Cảm biến lưu lượng
Xuất sứ: The Netherlands
Nhà cung cấp: ANS Đà Nẵng
Hãng sản xuất: BRONKHORST VIET NAM
Measurement / control system |
|
---|---|
Flow range |
min. 0,1…5 g/h |
Mass flow accuracy |
Liquid: ±0,2% of rate; |
Turndown |
up to 1:100 |
Repeatability |
±0,05% of rate ± ½(ZS* x 100/actual flow)% |
Zero Stability (ZS)* |
< ±0,02 g/h |
Response time, meter (t98%) |
≤ 200 msec |
Operating temperature |
0…70°C; |
Temperature effect** |
on zero: < 0,01 g/h/°C; |
Temperature accuracy |
±0,5°C |
Density accuracy |
< ±5 kg/m3 |
Mounting*** |
Any position, attitude sensitivity negligible |
Leak integrity |
Outboard < 2 x 10-9 mbar l/s He |
Warm-up time |
> 30 min. for optimum accuracy |