linear-transducer-12.png
Supply
Supply voltage
24 VDC, -20…+10 %
Current consumption no load  
<= 100 mA
Measuring principle  
magnetostrictive
Measuring length, standard  
50…2000 mm, in steps
Resolution  
0.1 mm
Linearity deviation  
± 0.20 mm <= 2000 mm
Reproducibility  
0.1 mm
Hysteresis  
0.1 mm <= 2000 mm
Characteristics - Validity  
using original TR Magnets
Temperature coefficient  
< 8 µm/°C <= 500 mm
 
< 15 ppm/°C FS > 500 mm
FS:
Full-Scale
Straight line velocity  
no restrictions
Mounting position  
no restrictions
Rod end mounting  
Option
Magnet  
T4-M33
 
other on request
CANopen - Interface
CANopen
EN 50325-4
Bus connection
ISO 11898-1, ISO 11898-2
CAN Specification 2.0 A
11-Bit Identifier
Device-Profile for Encoder
CiA DS406
Layer Setting Services, LSS
CiA DS305
Layer Management Services, LMT
CiA DS205-1, DS205-2
Transmission rate
Specific value
10, 20, 50, 100, 125, 250, 500
Specific value
800, 1000 kbit/s
Specific value
Default: 500 kbit/s
Adjustability
by means of rotary-switches
Adjustability
via LSS service, LMT service
Parameter/Function, changeable  
Resolution
 
Node-ID
 
Preset parameter
 
Transmission rate
 
Counting direction
 
Velocity parameter
Type of parametrization  
programmable
Programming - Tool  
Fieldbus-Device
 
TR-Soft: TRWinProg
Cycle time internal, <= 2.00 m  
2.00 ms
Optional Magnets
Number of magnets
3
Magnet - Minimum distance
80 mm