Supply
Supply voltage
24 VDC, -20…+10 %
Current consumption no load
<= 150 mA
Measuring principle
magnetostrictive
Measuring length, standard
50…4000 mm, in steps
Resolution
0.001 mm
Linearity deviation
typically ± 30 µm
± 0.05 mm < 1000 mm
± 0.1 mm >= 1000…1500 mm
± 0.15 mm > 1500 mm
Reproducibility
0.005 mm
Hysteresis
typically < 10 µm
< 0.02 mm < 1000 mm
< 0.1 mm >= 1000…1500 mm
< 0.15 mm > 1500 mm
Characteristics - Validity
using original TR Magnets
Temperature coefficient
< 8 µm/°C <= 500 mm
< 15 ppm/°C FS > 500 mm
FS:
Full-Scale
Straight line velocity
no restrictions
Mounting position
no restrictions
Material - Measuring body
Cr/Ni - alloy
Rod end mounting
Option
Magnet
T4-M33
other on request
PROFINET IO - Interface
PROFINET IO – Device
IEC 61158, IEC 61784-1
Physical Layer
Fast Ethernet, ISO/IEC 8802-3
PROFINET-Specification
V2.3
Conformance Class
B, C
Real-Time-Classes
Class 1, 2 (RT), Class 3 (IRT)
Media Redundancy Protocol, MRP
yes, is supported
PNO Encoder-Profile
Class 3 and 4, V4.2
Fast Start-Up (FSU)
3-times faster start-up
Transmission rate
Specific value
100 MBit/s
Cycle time
>= 1000 µs (IRT/RT)
Parameter/Function, changeable
Addressing
Resolution
Number of magnets
Interpolation
Preset parameter
Position averaging
Counting direction
Velocity parameter
Type of parametrization
programmable
Programming - Tool
Fieldbus-Device
TR-Soft: TRWinProg
Cycle time internal, <= 0.50 m
0.50 ms
Cycle time internal, <= 1.00 m
1.00 ms
Cycle time internal, <= 2.00 m
1.50 ms
Optional Magnets
Number of magnets
30
Magnet - Minimum distance
80 mm