linear-transducer-11.png
Supply
Supply voltage
12…24 VDC ± 10 %
Current consumption no load  
<= 100 mA
Measuring principle  
magnetostrictive
Measuring length, standard  
50…2500 mm
Linearity deviation  
± 0.04 % + 1 LSB
Hysteresis  
0.1 mm
Characteristics - Validity  
using original TR Magnets
Temperature coefficient  
100 ppm/°C FS
FS:
Full-Scale
Straight line velocity  
no restrictions
Mounting position  
no restrictions
Material - Measuring body  
Cr/Ni - alloy
Magnet  
T4-M33, T4-M22, T4-M20
Analog - Interface
Voltage/Current
Factory setting
Resolution
12 Bit D/A converter
Voltage output
0…+10 VDC
Current output
0…24 mA
Load resistance (I)
<= 250 Ohm
Parameter/Function, changeable  
Analog Voltage/Current
 
Counting direction
Type of parametrization  
Factory setting
Cycle time, internal  
<= 2 ms
External inputs
F/R
Count direction
Logic level
"0“ < +2V, "1“ = Supply