Supply
Supply voltage
9…36 VDC
Current consumption no load
<= 100 mA
Measuring principle
magnetostrictive
Measuring length, standard
50…3000 mm
Resolution
0.1 mm
Linearity deviation
± 0.04 % + 1 LSB
Hysteresis
0.1 mm
Characteristics - Validity
using original TR Magnets
Temperature coefficient
± 15 ppm/°C FS, typically
± 30 ppm/°C FS
FS:
Full-Scale
Straight line velocity
no restrictions
Mounting position
no restrictions
Material - Measuring body
Cr/Ni - alloy
Magnet
T4-M33, T4-M22, T4-M20
SSI - Interface
SSI-Clock input
Optocoupler
SSI-Data output
RS-422, 2-wire
Parameter/Function, changeable
Resolution
Output code
Counting direction
Cycle time internal, <= 1.00 m
1.00 ms
Cycle time internal, <= 1.50 m
1.50 ms
Cycle time internal, <= 2.00 m
2.00 ms
Cycle time internal, <= 2.50 m
2.50 ms