linear-transducer-18.png
Supply
Supply voltage
9…36 VDC
Current consumption no load  
<= 100 mA
Measuring principle  
magnetostrictive
Measuring length, standard  
50…3000 mm
Resolution  
0.1 mm
Linearity deviation  
± 0.04 % + 1 LSB
Hysteresis  
0.1 mm
Characteristics - Validity  
using original TR Magnets
Temperature coefficient  
± 15 ppm/°C FS, typically
 
± 30 ppm/°C FS
FS:
Full-Scale
Straight line velocity  
no restrictions
Mounting position  
no restrictions
Material - Measuring body  
Cr/Ni - alloy
Magnet  
T4-M33, T4-M22, T4-M20
SSI - Interface
SSI-Clock input
Optocoupler
SSI-Data output
RS-422, 2-wire
Parameter/Function, changeable  
Resolution
 
Output code
 
Counting direction
Cycle time internal, <= 1.00 m  
1.00 ms
Cycle time internal, <= 1.50 m  
1.50 ms
Cycle time internal, <= 2.00 m  
2.00 ms
Cycle time internal, <= 2.50 m  
2.50 ms