linear-transducer-7.png
Supply
Supply voltage
24 VDC, -20…+10 %
Current consumption no load  
<= 300 mA
Measuring principle  
magnetostrictive
Measuring length, standard  
50…4000 mm, in steps
Resolution  
0.001 mm, 3 magnets
 
0.05 mm, 30 magnets
Linearity deviation  
± 0.10 mm <= 1500 mm
 
± 0.15 mm > 1500 mm
Reproducibility  
0.005 mm
Hysteresis  
0.02 mm <= 1500 mm
 
0.1 mm > 1500 mm
Characteristics - Validity  
using original TR Magnets
Temperature coefficient  
< 8 µm/°C <= 500 mm
 
< 15 ppm/°C FS > 500 mm
FS:
Full-Scale
Straight line velocity  
no restrictions
Mounting position  
no restrictions
Material - Measuring body  
Cr/Ni - alloy
Rod end mounting  
Option
Magnet  
T4-M33
 
other on request
EtherCAT - Interface
EtherCAT
IEC 61158-1–6, IEC 61784-2
Physical Layer
Fast Ethernet, ISO/IEC 8802-3
Device profile
CoE, CiA DS-406
Transmission rate
Specific value
100 MBit/s
Cycle time  
100…20000 µs
Parameter/Function, changeable  
Resolution
 
Observer
 
Interpolation
 
Preset parameter
 
Counting direction
Type of parametrization  
programmable
Programming - Tool  
Fieldbus-Device
 
TR-Soft: TRWinProg
Cycle time internal, <= 0.50 m  
0.50 ms
Cycle time internal, <= 1.00 m  
1.00 ms
Cycle time internal, <= 2.00 m  
1.50 ms
Cycle time internal, <= 3.00 m  
2.00 ms
Cycle time internal, > 3.00 m  
4.00 ms
Optional Magnets
Number of magnets
3, 30
Magnet - Minimum distance
80 mm