a Vietnam Correct Model:PTU3031B01A1BCPK1A0A1AAB1B0A
Correct: Humidity and Temperature Transmitter PTU3031B01A1BCPK1A0A1AAB1B0A
Pressure range: 500...1100 hPa, Probe cable length : 2 m cable, +80 °C, no additional temperature probe, Graphical display with keypad. Power supply: 10...35 VDC, 24 VAC
Output signal: RS232C + Analog outputs (Ch1 & Ch2, optional Ch3), Cable gland M20*1.5
Pressure fitting: Barbed fitting for 1/8" hose
Humidity sensor: General purpose and high chemical concentrations - HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting, spare: DRW010281SP
Probe installation accessories : Duct Installation kit, item 215003
(PTU3031B1A1BCPK1A0A1AB1B0A)
Vaisala Vietnam Model: DM70K0A0A0B1
Hand-held Dewpoint Meter, Indicator type: alkaline batteries only, no indicator accessories
Probe type: DMP74A -40…+60°C Td, no accessories, no connection cable, no carrying case**
Vaisala Vietnam Model:HMT3305M0B121BCAE111G0CCGBEA1
Humidity and Temperature Transmitter
Cable length: 5 m cable =) Cuộn Tròn Được
No additional temperature probe
Parameters: RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
Display: Graphic LCD with backlight
Power Supply: Universal AC-power (100...240 VAC)
Cable bushings: Bushing Set (Cable gland M20 x 1.5 and Conduit fitting NPT1/2")
Humidity sensor type with chemical purge function, spare: HUMICAP180RC
Sensor protection: Sintered stainless steel filter, spare: HM47280SP
Installation kit for probe: Mounting flange, item: 210696
PC Accessories: MI70LINK software for Windows® with USB service cable, item: 219916
Vaisala Vietnam Correct Code:HMT3307S0A011BBAB120A0AACBAA
(HMT3307S0A01BBAB120A0AACBAA)
Humidity and Temperature Transmitter 
Cable length: 2 m cable =) Cuộn tròn được
Parameters: RH+T, Signal output : 4... 20 mA.
Power supply: 10..35 VDC, 24 VAC with galvanic isolation,  
Option for module slot 1: RS-485 serial interface (galvanically isolated)
Cable bushings: Cable gland M20 x 1.5
Humidity sensor type: General purpose and high chemical concentrations HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting DRW010281SP
Installation kit for probe: Duct installation kit, item: 210697
Vaisala Vietnam Model: D08A-24TS2
Vaisala Vietnam Model: DM70F1B1A4B
Portable dewpoint meter
Indicator type :rechargable with all AC adapters
indicator Accessories: MI70LINK software with RS232 cable (MI70LINK)
Probe type: DMP74B -60…+20°C Td
Pro accessories: sampling cell DSC74
Connection Cable to a Transmitter: no
Carrying Case : soft carrying case (MI70SOFTCASE)
Vaisala Vietnam Model: 213107SP
10 m extension cable for the MI70 probes
Vaisala Vietnam Model: HMD82
Humidity and Temperature Transmitter, 2-wire HMD82
Vaisala Vietnam Model: HMD82
Humidity and Temperature Transmitter, 2-wire HMD82
Vaisala Vietnam Model: DM70B0A2A4B1
Hand-held Dew-point Meter DM70B0A2A4B1
Indicator with Euro AC-Adapter, No Accessories
Probe type: Dewpoint probe for MI70 indicator, higher Td's
Probe Accessories: DM70 Portable Sampling System (DSS70A)
Connection Cable to a Transmitter: no
Carrying Case: soft carrying case (MI70SOFTCASE)
Vaisala Vietnam Part No.: DSS70A
DM70 Spare Parts and Accessories
Type: Portable sampling system
Vaisala Vietnam Model: HM70F4B1B0DB
Hand-held Humidity and Temperature Meter  HM70F4B1B0DB
Indicator type: rechargeable with all AC-adapters
Indicator accessories: MI70LINK software with USB cable (219687) Probe type: HMP76
Probe accessories: probe holder for HMP76/76B **
Vaisala Vietnam Humidity and Temperature Transmitter HMT 334 H0A101BCAC100B01DFBAA1
Cable length: 2 m cable for 232 mm probe
Parameters: RH+T
Display: Graphic LCD with backlight
Power supply: 10...35 VDC , 24 VAC
Cable bushings: Conduit fitting NPT1/2"
Humidity sensor type: General purpose HUMICAP180, spare: 15778HM
Sensor protection: Stainless steel grid, spare: HM47453SP
Installation kit for probe: Pressure fitting NPT 1/2"
Vaisala Vietnam Humidity and Temperature TransmitterHMT338 V0A101BCAC100B01DNBAA1
Cable length: 2 m cable for 232 mm probe
Parameters: RH+T
Display: Graphic LCD with backlight
Power supply: 10...35 VDC , 24 VAC
Cable bushings: Conduit fitting NPT1/2"
Humidity sensor type: General purpose HUMICAP180, spare: 15778HM
Sensor protection: Stainless steel grid, spare: HM47453SP
Installation kit for probe: Pressure fitting NPT 1/2"
Vaisala Vietnam Model: HMT360-0A22BCC1A7B00000
Humidity and Temperature Transmitter, Parameters RH+T
Display on transmitter cover
Interface cable connection: Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm
Ex certification and issuer: TIIS (Japan)
Vaisala Vietnam Model:HMT3304H0A101BCAC100B01DFBAA1
Humidity and Temperature Transmitter, Cable length: 2 m cable, Parameters RH+T, Display: Graphic LCD with backlight
Power supply: 10...35 VDC , 24 VAC
Cable bushings (Note: The Universal AC power not connected through 8-pole connector): Conduit fitting NPT1/2"
Humidity sensor type: HUMICAP180, spare: 15778HM
Sensor protection: Stainless steel grid, spare: HM47453SP
Installation kit for probe: Fitting body NPT 1/2"
Vaisala Vietnam Model:HMT3308V0A101BCAC100B01DNBAA1
Humidity and Temperature Transmitter, Cable length: 2 m cable for 232 mm probe, Display: Graphic LCD with backlight
Power supply: 10...35 VDC, 24 VAC
Cable bushings (Note: The Universal AC power not connected through 8-pole connector): Conduit fitting NPT1/2"
Cable bushings (Note: The Universal AC power not connected through 8-pole connector): Conduit fitting NPT1/2"
Humidity sensor type: HUMICAP180, spare: 15778HM
Sensor protection: Stainless steel grid, spare: HM47453SP
Installation kit for probe: Pressure fitting NPT 1/2"
Vaisala Vietnam Model: PTB330A0ACHHACFB0A0B
Digital Barometer, Accuracy Class A, No Display
Power Supply: Standard (10...35V,24VAC)
Signal output: Analog Output 4...20mA
Optional Module (Slot 3): 500...1100hPa
Optional Module (Slot 4):  Additional Baro Module 500..1100hPa
Customer Connection: Cable Bushing for 10..14mm cable
Pressure Fitting: Barbed Fitting 1/8", Two Barometer Modules
Vaisala Vietnam Humidity and Temperature TransmitterHMT3303E0A001BCAX100B01ACBAA1
Cable length 2 m cable, +80°C
Analog output signals for Ch1 , Ch2 and Ch3: special
Cable bushings: Conduit fitting NPT1/2" (Note: The Universal AC power not connected through 8-pole connector)
Sensor protection PPS plastic grid & stainless steel netting, spare: DRW010281SP
Installation kit for probe: Duct installation kit - item: 210697
Vaisala Vietnam Humidity and Temperature TransmitterHMT3303E0A001BCAX100B01ACBAA1
Cable length 2 m cable, +80°C
Analog output signals for Ch1 , Ch2 and Ch3: special
Cable bushings: Conduit fitting NPT1/2" (Note: The Universal AC power not connected through 8-pole connector)
Sensor protection PPS plastic grid & stainless steel netting, spare: DRW010281SP
Installation kit for probe: Duct installation kit - item: 210697
Vaisala Vietnam Code: DMT340-6Q0K 1B121A1A001A2D6K0C0
Type: Dewpoint Transmitter, Probe cable length: 5m cable
Dewpoint + mixing ratio (+ SSR + Ts)*, Graphical display with keypad, Power supply: 10...35 VDC, 24 VAC with galvanic isolation for outputs, Interface cable connection: Cable gland (for 8...11 mm cable) (for 0.315...0.433 inch cable)
Sensor: DRYCAP®180S
Probe installation accessories: With cooling set
Vaisala Vietnam Code: DMT340-6Q0K 1B121A1A001A2D6K0C0
Type: Dewpoint Transmitter, Probe cable length: 5m cable
Dewpoint + mixing ratio (+ SSR + Ts)*, Graphical display with keypad, Power supply: 10...35 VDC, 24 VAC with galvanic isolation for outputs, Interface cable connection: Cable gland (for 8...11 mm cable) (for 0.315...0.433 inch cable)
Sensor: DRYCAP®180S
Probe installation accessories: With cooling set
Vaisala Vietnam Code: HMT330-3E0A001BCAX100B01ACBAA1
Humidity and Temperature Transmitter
Vaisala Vietnam Code: HMT330-3E0A001BCAX100B01ACBAA1
Humidity and Temperature Transmitter
Vaisala Vietnam Hand-Held Humidity and Temperature meter Standard Probe HM41
(HM34)
Vaisala Vietnam Correct Code: HMT330-3F0B001BCAC100A0AACBAA1
Vaisala HUMICAP® Humidity and Temperature Transmitter
Cable length: 5 m cable, +80°C
Parameters: RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
Humidity sensor type: General purpose and high chemical concentrations HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting DRW010281SP
Installation kit for probe: Duct installation kit 210697
Vaisala Vietnam Code: HMD60U
Humidity Transmitter, 2-wire
Vaisala Vietnam Code: HMD60U
Humidity Transmitter, 2-wire
Cognex Vietnam Model: DMR-8600-0100
DATAMAN 8600 Handheld ID Reader with Serial
Communication Module
Cognex Vietnam Model: DM100-PWR-000
DataMan 100 Power Supply
Cognex Vietnam Model: DM8000-RS232-05
DM 8000 RS-232 COILED CBL 4M
Cognex Vietnam Model: DM8500-USBC-02
DM 8000 COILED USB CABLE 2.5M
Cognex Vietnam Model: DMA-WALL-8000-00
DATAMAN 8000 WALL MOUNT BKT
Vaisala Vietnam Code: PTB1105A0AB
Type: Barometer PTB110, Pressure Range 800-1060 hPa
Output: PTB110 Output 0 ... 5 Vdc, Installation Kit
Pressure Fitting: Pressure Connector M5 (10-32)
Vaisala Vietnam Code: PTB1105A0AB
Type: Barometer PTB110, Pressure Range 800-1060 hPa
Output: PTB110 Output 0 ... 5 Vdc, Installation Kit
Pressure Fitting: Pressure Connector M5 (10-32)
Vaisala Vietnam HMI41SET-D-5-B has obsoleted already,The replacing product is HM46. 
Code: Humidity and Temperature Meter HM46
The package includes:
HM46 humidity and temperature meter
Calibration certificate (ISO9001 compliant, NIST traceable)
Light carrying case
Alkaline batteries 2 x AA sized, 1.5V (LR6)
User's Guide in English
Note: Please note that this new probe does not match with the old type of indicator (HMI41)
Vaisala Vietnam HMI41SET-D-5-B has obsoleted already,The replacing product is HM46. 
Code: Humidity and Temperature Meter HM46
The package includes:
HM46 humidity and temperature meter
Calibration certificate (ISO9001 compliant, NIST traceable)
Light carrying case
Alkaline batteries 2 x AA sized, 1.5V (LR6)
User's Guide in English
Note: Please note that this new probe does not match with the old type of indicator (HMI41)
Vaisala Vietnam Model: HMW89
Humidity and Temperature Transmitter HMW89
Vaisala Vietnam Model: HMW89
Humidity and Temperature Transmitter HMW89
E+E Elektronik Vietnam Type: HUMOR 20
High accuracy humidity calibrator series HUMOR 20
 
E+E Elektronik Vietnam Type: HA020201
Cover for measuring chamber 12 - 16 mm / 2 inserts
E+E Elektronik Vietnam Type: HA020202
Cover for measuring chamber 16 - 20,5 mm / single insert
E+E Elektronik Vietnam Type: HA020203
Cover for measuring chamber 20,5 - 25,5 mm / single insert
E+E Elektronik Vietnam Type: HA020204
Cover for measuring chamber 8 - 12 mm / 3 inserts
E+E Elektronik Vietnam Type: HA020205
Cover for measuring chamber 12mm / 4 inserts
E+E Elektronik Vietnam Type: HA020207
Cover for measuring chamber 12 - 16 mm / 4 inserts
 
E+E Elektronik Vietnam Type: HA020301
Automatic calibration kit
E+E Elektronik Vietnam Type: HA0201xx
Compressor for filtered, oil free air (xx - see datasheet for compatible voltage)
E+E Vietnam Replaced by: EE381-TEHA07/BK6-T33
Eplusle Vietnam (EE385-TEHA07/BK6-T33)
  Model:  transmitter, Pressure range: up to 20bar
  Pressure tight feedthrough: ½”NPT thread
  Display: without display, Type of Signal: 4…20mA
  Output 1: temperature [-40…160°C]
  Output 2:  water activity [0…1 aw]
Vaisala Vietnam Model: M0B121BCAE111G0CCGBEA1
Humidity and Temperature Transmitter HMT335 
Cable length: 5 m cable
Parameters: RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT
Display: Graphic LCD with backlight
Power supply: Universal AC-power (100...240 VAC)
Signal output for Ch1 , Ch2 and Ch3: 4... 20 mA, (0... 100%RH), -40...+180°C
Option for module slot 1: Relay output
Cable bushings: Bushing Set (Cable gland M20 x 1.5 and Conduit fitting NPT1/2")
Humidity sensor type: with chemical purge function, spare: HUMICAP180RC
Sensor protection: Sintered stainless steel filter, spare: HM47280SP
Installation kit for probe: Mounting flange - item: 210696
PC Accessories: MI70LINK software for Windows® with USB service cable - item: 219916
Vaisala Vietnam Model: HMT330-3E0A101BCAF100A0AAABAA1
HUMICAP® Humidity and Temperature Transmitter
Cable length: 2 m cable, +80°C, Parameters: RH+T
Display: Graphic LCD with backlight
Power supply: 10...35 VDC , 24 VAC
Signal output: 4... 20 mA, 0... 100%RH, -20...+60°C
Cable bushings : Cable gland M20 x 1.5
Humidity sensor type: General purpose and high chemical concentrations, HUMICAP180R - spare: HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting - spare: DRW010281SP
Vaisala Vietnam Model: HMP60-A12A0A1B0
Humidity and Temperature Probe, Output signals: 0...1 V
Measured parameter for channel 1: RH
Measured parameter for channel 2: temperature (-40 ...+60°C), Sensor protection: Plastic grid with filter
Humidity sensor: Intercap, Probe cable length: No cable
Vaisala Vietnam Code: HMP155 A2GB11A0A1A1B0A
Meteorological probes 
Probe type: 2 x voltage output (RS458 for service use)
Signal output: Analog Output (CH1+CH2) Output 0...1V
T (-40...+60´C), RH (0...100%RH)
Humidity sensor type: H180R and Separate PT100 incl. shrinkable tubing
Probe cable lenghth: 3.5 m (with 8 pin M12 female connector), RH&T-calibration in  room temperature
Vaisala Vietnam Model: HMT330-1A0A101BCAB100A1AAABAA1
Vaisala HUMICAP® Humidity and Temperature Transmitter
Wall probe: fixed, No additional temperature probe
Parameters: RH+T
Display: Graphic LCD with backlight
Power supply: 10...35 VDC , 24 VAC
Signal output for Ch1 , Ch2 and Ch3: Analog output channel (Ch1&Ch2&Ch3): 4... 20 mA, RH: (0...100%RH), T: -40...+60°C Analog output signals: No 3rd analog output
Cable bushings : Cable gland M20 x 1.5
Transmitter installation: Wall mounting plate (item: 214829)
Humidity sensor type: General purpose and high chemical concentrations, HUMICAP180R, spare: HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting - spare: DRW010281SP
Vaisala Vietnam Model: HMT330-1A0A101BCAB100A1AAABAA1
Vaisala HUMICAP® Humidity and Temperature Transmitter
Wall probe: fixed, No additional temperature probe
Parameters: RH+T
Display: Graphic LCD with backlight
Power supply: 10...35 VDC , 24 VAC
Signal output for Ch1 , Ch2 and Ch3: Analog output channel (Ch1&Ch2&Ch3): 4... 20 mA, RH: (0...100%RH), T: -40...+60°C Analog output signals: No 3rd analog output
Cable bushings : Cable gland M20 x 1.5
Transmitter installation: Wall mounting plate (item: 214829)
Humidity sensor type: General purpose and high chemical concentrations, HUMICAP180R, spare: HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting - spare: DRW010281SP
Vaisala Vietnam Code: HMT330-180B111XDBX100B11AABAA1
Vaisala HUMICAP® Humidity and Temperature Transmitter
Wall probe with short cable, Probe holder plate recommended in selection 16
No additional temperature probe
Vaisala Vietnam Code: HMT330-3G0B111BCAX100B11ACBAA1
Vaisala HUMICAP® Humidity and Temperature Transmitter
Cable length: 10 m cable, +80°C
Vaisala Vietnam Item no: 219980 SP
Connection cable for MI70 (to HMW90)
Vaisala Vietnam Item no: 219980 SP
Connection cable for MI70 (to HMW90)
Vaisala Vietnam Model: PTB330B0ACHAACEC1A0B
Digital Barometer (class B, equipped with 1 pressure transducer)
Accuracy Class: Class B, No Display
Power Supply: Standard (10...35V,24VAC)
Signal Output: Analog Output 4...20mA
Pressure Range: 500...1100hPa
Optional Module (Slot 3): No Module
Optional Module (Slot 4) : No Module
Customer Connection: Cable Bushing for 10..14mm cable
Pressure Fitting: Barbed Fitting 1/8", One Barometer or Differential Measurement
Optional Connection: Cable Bushing for 10..14mm cable
Installation: Wall Mounting Kit
Calibration: No Calibration Contract ISO9001 Calibration
Service Contract: No Maintenance Contract
User′s Guide: User´s Guide PTB330 English
Vaisala Vietnam Vaisala  Hand-held Indicator MI70B13
Indicator accessories: MI70Link with RS232 and analog output signal cables
Vaisala Vietnam Model: HM40D1BB
Vaisala HUMICAP® Humidity and Temperature Meter
Probe: Stainless steel probe (HM46PROBE) with sintered filter (HM46), Batteries: Alkaline batteries, Case: For long probes
User's guide language: English
Vaisala Vietnam Vaisala DRYCAP® Dewpoint Transmitter DMT152 for very dry conditions,  measurement range down to -80°C Td/f  . 
Code: DMT152-A1DCE11A330A1X
Mechanical connection: ISO G1/2" thread
Measurement parameters: Td/f, ppm
Analog output Ch1 & Ch2 + RS-485 as standard: 4...20 mA
Analog output parameter or function for Ch1: Td/f, -100...0 °C, -148...+ 32 °F
Analog output parameter or function for Ch2: ppm, 0...500 ppm
Output units: Metric units (Celsius)
Pressure setting for ppm calculation: Ambient 1 bara / 14,76 psia
Sensor Protection: Stainless steel mesh filter
Cable for analog outputs and power supply (Port I): 3 m (9.8 ft) shielded cable with threaded connector
Cable for analog outputs and power supply (Port II): 3 m (9.8 ft) shielded cable with threaded connector
Installation accessories ONLY for ISO1/2" thread: None
Special features: None
Package: Standard cardboard
User' s guide: Multilingual quick guide
Vaisala Vietnam Code: HMT 330 1A0A101BCAB126A4AAABEA1
Vaisala HUMICAP® Humidity and Temperature Transmitter HMT330, Wall probe: fixed, No additional temperature probe
Parameters: RH+T, Display: Graphic LCD with backlight
Power supply: 10...35 VDC , 24 VAC
Signal output for Ch1 , Ch2 and Ch3: Analog output channel (Ch1&Ch2&Ch3): 4... 20 mA, Output units: Metric
RH: (0...100%RH), T: (range: see below)
Analog output signals: No 3rd analog output
Analog output range for temperature: -40...+60°C (-40...+140°F)
Option for module slot 1: RS-485 serial interface (galvanically isolated)
Option for module slot 2: Data logger module - Not possible if the data logger module has already been chosen in item 13
Cable bushings: Cable gland M20 x 1.5
Transmitter installation: DIN rail kit- item: 215094
Humidity sensor type: General purpose and high chemical concentrations, HUMICAP180R, spare: HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting, spare: DRW010281SP, No probe installation kit
Operating manual language: English
PC Accessories: MI70LINK software for Windows® with USB service cable - item: 219916
Calibration: ISO9001 compliant factory calibration
Vaisala Vietnam Code: HMT310 3A5A1BCD14B7AA1A2
Type: HUMICAP® Humidity and Temperature Transmitter, Probe for general use, Parameters: RH+T
Mounting plate: Standard mounting plate (recommended choice)
Power supply: 24 VDC
Analog output signal for Ch1 and Ch2: 4... 20 mA & RS232C,
RH: (0... 100%RH), all probes
Temperature: (choose T range below), all probes
Analog output range for temperature: -40...+120°C, (-40...+248°F)
Output units: Metric
Cable connector: 8-pole connector with5m cable, spare 5 m cable: 212142
Operating manual language: English
Probe type: HMP303, with 10 m cable, +120°C
Humidity sensor type: General purpose, HUMICAP180R
Sensor protection: PPS plastic grid & stainless steel netting (recommended for HMP303 and HMP307)