safety-relay-type-ue10-3os4d0-p-n-1028303.png
đẶT ĐIỂM
Safety integrity level SIL3, SILCL3 (IEC 61508, EN 62061) 1) 1)
Category Category 4 (EN ISO 13849) 1)
Performance level PL e (EN ISO 13849) 1)
B10d parameter 1.26 x 106 switching cycles, 5.9 x 106 switching cycles, 4.35 x 105 switching cycles, 1 x 107 switching cycles (AC-15, 230 V, I = 1.5 A, AC-15, 230 V, I = 0.75 A, DC-13, 24 V, I = 2.5 A, DC-13, 24 V, I = 0.63 A)
PFHD (mean probability of a dangerous failure per hour) 3.0 x 10-8 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)